Home ﹥ Products > Power Distribution > IP Metered-Switched PDUs > 16 outlet IEC60320 C13 Remote switching power supply measurement socket 20A
16 outlet IEC60320 C13 Remote switching power supply measurement socket 20A
You could get the Instant power usage information included from a near-end LCD screen or remote browser.
You can control the PDU power outlet switch from the remote end.
-
You can control the PDU power outlet switch from the remote end.
-
You can monitor the total power consumption of the entire PDU at the
remote location through the webpage.
-
Trap Email notification will be automatically sent immediately when a
power anomaly occurs.
-
Warning method: Email (you can set the second stage warning limit:
alarm and overload.
-
Support communication protocol: Http, TCP/IP, DHCP, UDP, SNMP.
-
Support power sequence start setting, which can be used to set the power-on
and power-off time of each power device. -
Configure 6 digits LCD digital meter (True RMS) which could read the
precision electricity information included : V (voltage),A (current),W (watt),Hz (frequency), VA(apparent power), PF(power factor), kWh (kilowatt hour).
-
LCD digital meter could display the grand total electricity (kWh,kilowatt
hour) of PDU and zero return statistics.
-
Surge Protection: Max total surge absorb current 6,500A.ax total surge
absorb energy : 220J Joule.
-
Recoverable 20A Overload protection device (with 20A breaker protector)
-
LCD digital meter with backlight display to display meter values in a
dark environment· Plug and sockets design in the front side. Power cord on the rear side.
-
If the meter fails, the PDU can continue to supply power.
-
Included Anti-shedding power socket design. Effectively prevent the
power cord from falling off
-
Complied with UL safety certification power plug, sockets,breaker
protector compnents.
-
Chassis material: Galvanized steel sheet, thermosetting power paint.
The outer surface is completely insulated.
-
Rackmount hanger installable in the 19 inches Cabinet. 0U mounted
forward, backward vertically.
-
The maximum total current can be selected from 15A, 20A, 30A.
-
The input plug can be customized to 5-15P, L5, L6 plug or other special specifications; the length of power cord can be customized.
Specification
PDU-IS-C13(16)-515P
Interface
Output Socket
(16) IEC60320 C13
Input Plug
(1) NEMA 5-15P With inseparable 3 meters standard power cord
Electrical Characteristics
Operation Voltage
100V ~240V AC
Frequency
50~60Hz
Overload Protection
20A (Ampere) Recoverable Breaker Protector *1pcs
Surge Protection Value
Max Allowance Voltage: ACrms(V)300
Max Absorb Energy: 220J Joule
Max Current: 6,500A
Operation Temperature
0~50℃
Storage Temperature
-20~60 ℃
Humidity
Humidity: 10~90%
Outline Dimensions
878 x 70 x 44 mm ( WDH)
Net Weight2
2.5 kg